The Smart Knee®

By combining the power of Persona® The Personalized Knee® with CANARY canturioTM te with CHIRP system, Persona IQ is smart, connected and simple. 

  • Supports the goal of 100% patient compliance
  • Provides remote, automatic internal medical data through an intuitive user interface
  • Maintains standard Persona Knee surgery workflow and instrumentation

Persona IQ was designed to empower you with Smart post-operative metrics, ensure you’re Connected with your patients through the mymobility® Care Management Platform, and Simple to use with automated data flow and an intuitive user interface.

Learn more about Persona IQ

Persona IQ Customer Testimonials

See what patients are saying about Persona IQ

Persona IQ Brand Anthem Video

Discover how we are taking the next steps in orthopedic innovation.

Persona IQ Customer Testimonials

See what patients are saying about Persona IQ

Persona IQ Brand Anthem Video

Discover how we are taking the next steps in orthopedic innovation

Features

Smart

Smart

  • First-to-world smart implant that captures key kinematic data metrics
  • The objective kinematic data is an adjunct to other physiological parameter measurement tools applied by the physician during the course of patient monitoring and treatment post-surgery

Connected

Connected

  • Provides a direct view of patient-specific data for at least ten years
  • Supports the goal of patient compliance

Simple

Simple

  • The long-term data is automatically available, through a simple to use intuitive interface for both patients and physicians to view 
  • Maintains standard Persona Knee surgery workflow and instrumentation

Smart

  • First-to-world smart implant that captures key kinematic data metrics
  • The objective kinematic data is an adjunct to other physiological parameter measurement tools applied by the physician during the course of patient monitoring and treatment post-surgery

Connected

  • Provides a direct view of patient-specific data for at least ten years
  • Supports the goal of patient compliance

Simple

  • The long-term data is automatically available, through a simple to use intuitive interface for both patients and physicians to view on the mymobility® Care Management Platform
  • Maintains standard Persona® Knee surgery workflow and instrumentation

Privacy

We understand the importance of privacy and are dedicated to protecting that right. We only use customer and patient data to provide the services we’ve agreed upon and for purposes that will enable those services. Persona IQ is not designed to track patient location, and Zimmer Biomet will protect the data you entrust us with through strong safeguards.

Privacy

Security

Usage

Ownership

Privacy

Security

Usage

Ownership

System Information

Persona IQ is a first-to-world smart knee implant that captures relevant gait metrics including functional knee range of motion (ROM), step count, and sampled average walking speed. By utilizing sensor-based technology, Persona IQ allows physicians and care teams to collect patient-specific data during the course of patient monitoring.

85

Cadence

Average steps taken per minute (steps/minute)

0:54

MPS

Average Walking Speed

Calculated based on step count and stride length (meters/second)

.74

M

Stride Length

Calculated based on one gait cycle (meters)

.89

KM

Distance Traveled

Calculated based on step count and stride length (km)

52

Functional Range of Motion

Including tibia and functional knee ROM (degree)

1201

Step Count

Number of steps taken during a sampling day

Secure Data Flow

The collection and utilization of patient-specific data is easy with Persona IQ. 

The post-operative data is available through a simple to use intuitive interface for both patients and physicians to view on the mymobility Care Management Platform.

Persona IQ with the mymobility Care Management Platform

mymobility provides support and guidance to patients through a connected experience collecting the following metrics. All you have to do is enroll.

  • Education & Engagement
  • PROMs Collection Exceptions (Pain & Gait)
  • Effortless Activity + Physiologic Tracking
  • Pre- and Post-Operative Exercises
  • Telemedicine (Virtual Visits) & Messaging

Indications and Contraindications

Indications

The Canary Tibial Extension (CTE) with Canary Health Implanted Reporting Processor (CHIRP) System is intended to provide objective kinematic data from the implanted medical device during a patient’s total knee arthroplasty (TKA) post-surgical care. The kinematic data are an adjunct to other physiological parameter measurement tools applied or utilized by the physician during the course of patient monitoring and treatment post-surgery.

The device is indicated for use in patients undergoing a cemented TKA procedure that are normally indicated for at least a 58 mm sized tibial stem extension.

The objective kinematic data generated by the CTE with CHIRP System are not intended to support clinical decision-making and have not been shown to provide any clinical benefit. The CTE with CHIRP System is compatible with Zimmer Persona® Personalized Knee System.

Contraindications

The canturio™te (CTE) is contraindicated for use in patients who are undergoing procedures or treatments at or in the proximity of the CTE using therapeutic ionizing radiation can result in shortened battery life or premature failure of electronic components. Damage to the CTE by therapeutic ionizing radiation may not be immediately detectable.

Before performing TKA on any patient, consider the following contraindications.

The Zimmer Biomet Persona® Knee System is contraindicated for use in patients who have—

  • Previous history of infection in the affected joint and/or other local/systemic infection that may affect the prosthetic joint
  • Insufficient bone stock on femoral or tibial surfaces
  • Skeletal immaturity
  • Neuropathic arthropathy
  • Osteoporosis or any loss of musculature or neuromuscular disease that compromises the affected limb
  • A stable, painless arthrodesis in a satisfactory functional position
  • Severe instability secondary to the absence of collateral ligament integrity

Total Knee Arthroplasty is contraindicated in patients who have rheumatoid arthritis (RA) accompanied by an ulcer of the skin or a history of recurrent breakdown of the skin because their risk of postoperative infection is greater. RA patients using steroids may also have increased risk of infection. Late infections in RA patients have been reported 24+ months postoperative.

 

Additional Information

Tailored resources for your patients

Find videos, articles, and interactive content to guide your patients throughout their surgical journey on ReadyPatient.com, our dedicated patient recovery site.

Reimbursement Information

Click here to view the Zimmer Biomet Coding Guide for Persona IQ.

CONTACT US TO DISCOVER MORE ABOUT PERSONA IQ!

SUBMIT YOUR INFORMATION AND GET CONTACTED BY A ZIMMER BIOMET REP

All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.

For indications, contraindications, warnings, precautions, potential adverse effects and patient counselling information, see the package insert or contact your local representative; visit www.zimmerbiomet.com for additional product information.

This material is intended for healthcare professionals. Distribution to any other recipient is prohibited.

Canary Medical Logo, Canary Medical, CANARY canturio™te, and CHIRP™ are the exclusive property of Canary Medical.

For full prescribing information for the CANARY canturio ™ te, refer to physician instructions for use.

©Zimmer Biomet 2022

Patients must have compatible internet access and a text-capable mobile device, or a smartphone to use mymobility; not all smartphone app features are available with web-based version.

Not all patients are candidates for the use of this product and surgeons should evaluate individually to determine which patients are appropriate for therapy at home.

All names used in the mymobility app examples are fictitious. No identification with actual patients or health care professionals is intended or should be inferred. Apple, iPhone and Mac are registered trademarks of Apple, Inc.

All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.

For indications, contraindications, warnings, precautions, potential adverse effects and patient counselling information, see the package insert or contact your local representative; visit www.zimmerbiomet.com for additional product information.

This material is intended for healthcare professionals. Distribution to any other recipient is prohibited.

Canary Medical Logo, Canary Medical, CANARY canturio™te, and CHIRP™ are the exclusive property of Canary Medical.

For full prescribing information for the CANARY canturio ™ te, refer to physician instructions for use.

©Zimmer Biomet 2022

Patients must have compatible internet access and a text-capable mobile device, or a smartphone to use mymobility; not all smartphone app features are available with web-based version.

Not all patients are candidates for the use of this product and surgeons should evaluate individually to determine which patients are appropriate for therapy at home.

All names used in the mymobility app examples are fictitious. No identification with actual patients or health care professionals is intended or should be inferred. Apple, iPhone and Mac are registered trademarks of Apple, Inc.